Heat pump guide: selection, sizing, consumption and installation

ECO-TEC technical guide. The information is indicative and structured from an HVAC&R technical-selection perspective. Final sizing must be correlated with the actual building load and the real installation.

In brief: how to choose a heat pump correctly

A heat pump should not be selected solely from the floor area of the house. Selection must correlate the heating load, outdoor design temperature, required flow temperature, emitter type, domestic hot-water demand and actual operating profile.

Two houses with the same floor area can have very different heating loads because of insulation, glazed surfaces, air infiltration, orientation and requested indoor temperature.

1. Sizing starts with the heating load

W/m² estimates are useful for a preliminary discussion, but they do not replace a heat-loss calculation. The actual capacity available at the relevant outdoor temperature and required water temperature must be checked.

Undersizing may increase the contribution of the auxiliary electric heat source. Excessive oversizing can lead to more frequent cycling and less efficient operation.

2. Flow temperature is essential

In general, heat-pump efficiency improves when the installation can operate with a lower required flow temperature. Underfloor heating is very suitable for this principle, while radiators can also work correctly when they are sized for the actual operating temperature regime.

3. COP and SCOP must be interpreted correctly

COP describes performance at a specific operating point. SCOP describes seasonal performance according to the assessment methodology applicable to the equipment. A high COP cannot be compared correctly without knowing the outdoor-air and water temperatures at which it was measured.

4. Monobloc or split?

Both solutions can be correct. In a monobloc unit the refrigerant circuit is contained in the outdoor unit and the connection to the building is hydraulic. A split system has a refrigerant connection between system units.

The choice depends on the project, location, pipe routes, frost protection, available space and installation requirements.

5. Heat pump with existing radiators

A heat pump can operate with radiators, but their output at the actual flow and return temperatures must be checked. Radiator output at a high-temperature regime is not the same as the available output at lower temperatures.

6. Domestic hot water

DHW preparation must be included in the design. The number of users, cylinder volume, requested temperature and consumption profile influence the system configuration.

7. Defrosting is normal

Air-to-water heat pumps can form ice on the heat exchanger under certain temperature and humidity conditions. The defrost cycle is a normal process and must be considered in hydraulic design and winter-operation assessment.

8. Outdoor-unit location

The manufacturer’s required distances and airflow must be respected, air recirculation must be avoided and drainage of condensate and defrost water must be provided. Service access and sound level should be considered during design.

9. What determines heat-pump consumption?

  • the building heating load;
  • outdoor temperature;
  • flow temperature;
  • requested indoor temperature;
  • DHW preparation;
  • equipment sizing;
  • controls and automation;
  • actual operating behaviour.

10. What data is needed to select the equipment?

  • project location;
  • heated floor area;
  • insulation level;
  • calculated heating load, if available;
  • underfloor heating, radiators or fan coils;
  • required flow temperature;
  • number of DHW users;
  • available electrical supply;
  • installation conditions.

Heat pumps available in the ECO-TEC catalogue

The following list is generated directly from the catalogue so that available products and technical information remain connected.

Frequently asked questions

What heat pump do I need for a 150 m² house?

Floor area alone is not enough. The heating load may vary significantly between two buildings with the same area.

Can a heat pump work with radiators?

Yes, if the radiators can provide the required output at the water temperatures at which the system will operate.

Is it better to buy a larger heat pump?

Not automatically. Capacity must be sized for the application; oversizing does not replace a heat-loss calculation.

What should be compared between two heat pumps?

Capacity under real operating conditions, COP and SCOP, maximum water temperature, operating range, sound level, controls, warranty and technical support.

What is the main information needed for sizing?

The building heating load at design conditions, correlated with the required flow temperature.

Guides for specific situations

Do you have a specific project?

Send us the building and installation data for a technical selection by the ECO-TEC team.